ENHANCEMENT OF LOW VOLTAGE RIDE THROUGH CAPABILITY GRID-CONNECTED PHOTO VOLTAIC POWER PLANTS BY USING VOLTAGE CONTROL METHOD
Author’s Name : C P Jeevana Priya | M Rama Subbamma
Volume 04 Issue 03 Year 2017 ISSN No: 2349-2503 Page no: 23-27
Abstract:
A full-scale permanent-magnet synchronous generator (PMSG)-based wind turbine with dc-link voltage control via the machine-side converter has the potential to provide inherent low-voltage ride-through (LVRT) performance without additional hardware components. However, several important performance aspects related to this topology are not addressed in this literature. This paper investigates the impacts of the LVRT control on the stability and risk of resonance, successful operation, and fatigue in a full-scale PMSG-based wind power generation system. An analytical model, considering the double-mass nature of the turbine/generator and typical LVRT requirements, is developed, validated, and used to characterize the dynamic performance of the wind generation system under LVRT control and practical generator characteristics. To enhance the operation and reduce the fatigue under LVRT control, two solutions, based on active damping control and dc-link voltage bandwidth retuning, are proposed, analyzed, and compared. The detailed nonlinear time-domain simulation results validate the accuracy of the developed model and analytical results.
Keywords:
A ging, fatigue, low-voltage ride-through, modeling, permanent-magnet synchronous generator (PMSG), stability, wind power generation
References:
- (2014). Global wind energy outlook. [Online]. Available: www.gwec.net.
- 20%Wind Energy by 2030, Increasing wind energy’s contribution to U.S. Electricity Supply. Washington, DC, USA, Jul. 2008, U.S. Department of Energy.
- “Wind by numbers: Economic benefits of wind energy,” Canadian Wind Energy Association [Online]. Available: http://www.canwea.ca
- S.De Rijcke, P. Tielens, B. Rawn,D.Van Hertem, and J. Driesen, “Trading energy yield for frequency regulation: Optimal control of kinetic energy in wind farms,” IEEE Trans. Power Syst., vol. 30, no. 5, pp. 2469–2478, Sep. 2015.
- M. F. M. Arani and Y. A. I. Mohamed, “Analysis and impacts of implementing droop control in DFIGs on microgrid/weak-grid stability,” IEEE Trans. Power Syst., vol. 30, no. 1, pp. 385–396, Jan. 2015.
- M. F. M. Arani et al., “Implementing virtual inertia in DFIG-based wind power generation,” IEEE Trans. Power Syst., vol. 28, no. 2, pp. 1373–1384, May 2013.
- (Apr. 2006). E. ON Netz GmbH, Grid Code: High and Extra High Voltage, Germany. [Online]. Available: http://www.eon-netz.com
- S.M.Muyeen, R. Takahashi, T.Murata, and J. Tamura, “A variable speed wind turbine control strategy to meet wind farm grid code requirements,” IEEE Trans. Power Syst., vol. 25, no. 1, pp. 331–340, Feb. 2010.
- R. Cardenas, R. Pena, S. Alepuz, and G. Asher, “Overview of control systems for the operation of DFIGs in wind energy applications,” IEEE Trans. Ind. Electron., vol. 60, no. 7, pp. 2776–2798, Jul. 2013.