IJREE – Volume 5 Issue 4 Paper 4

UNCERTAINITY AND INTERMITTENT OF WIND AND WAVE POWER USING DC MICRO GRID

Author’s Name :  L Siva Kumar Reddy

Volume 05 Issue 04  Year 2018  ISSN No: 2349-2503  Page no: 13 -18

12

Abstract:

Linear power damping synchronizing controller mechanically synchronizes with VSC to grid which enables full power injection under weak grid condition providing by damping with controllers stable and smooth operations also. But whenever sudden large disturbances occur in the system this controller may leads to affect the system stability. To overcome this difficulty a nonlinear controller is implemented. Thus the linear controller needs a nonlinear controller to improve the system stability under transient conditions. Nonlinear controller is used to supplement the linear controller and enhances the system stability and performance under large disturbances such as self-synchronization, disturbances in grid frequency, high power injection in very weak grids and fault ride through conditions. The main theme of this project to develop a new controller topology to connected to a voltage source converter to weak grids. The controller has two parts Linear power damping synchronizing controller. Non-linear controller.

Keywords:

Bidirectional DC/DC Converter, Bidirectional Grid-Tied Inverter, DC Microgrid, Load DC/DC Converter, Stability, Voltage-Source Converter (VSC), Wave Power Generator, Wind Power Generator

References:

  1. Y. Ito, Y. Zhongqing, and H. Akagi, “DC microgrid based distribution power generation system,” in Proc. 4th IEEE Int. Power Electron. Motion Control Conf., 2004, vol. 3, pp. 1740–1745.
  2. S. K. Kim, J. H. Jeon, C. H. Cho, J. B. Ahn,& S. H. Kwon,“ Dynamic modelling and control of a grid-connected hybrid generation system with versatile power transfer,” IEEE Trans. Ind. Electron., vol.55,no. 4, pp. 1677–1688, Apr. 2008.
  3. C. Abbey and G. Joos, “Supercapacitor energy storage for wind energy applications,” IEEE Trans. Ind. Appl., vol. 43, no. 3, pp. 769–776, May 2007.
  4. X. Liu, P. Wang, and P. C. Loh, “A hybrid ac/dc microgrid and its coordination control,” IEEE Trans. Smart Grid, vol. 2, no. 2, pp. 278–286, Jun. 2011.
  5. H. Kakigano, Y. Miura, and T. Ise, “Low-voltage bipolar-type dc microgrid for super high quality distribution,” IEEE Trans. Power Electron., vol. 25, no. 12, pp. 3066–3075, Dec. 2010.
  6. M. G. D. S. Prado, F. Gardner, M. Damen, and H. Polinder, “Modeling and test results of the Archimedes wave swing,” J. Power Energy, vol. 220, no. 8, pp. 855–868, Dec. 2006.
  7. B. Das and B. C. Pal, “Voltage control performance of AWS connected for grid operation,” IEEE Trans. Energy Convers., vol. 21, no. 2, pp. 353–361, Jun. 2006.
  8. E. Tara et al., “Dynamic average-value modeling of hybrid-electric vehicular power systems,” IEEE Trans. Power Del., vol. 27, no. 1, pp. 430–438, Jan. 2012.
  9. H. L. Do, “Nonisolated bidirectional zero-voltage-switching dc–dc converter,” IEEE Trans. Power Electron., vol. 26, no. 9, pp. 2563–2569, Sep. 2011.
  10. D. Salomonsson, L. Söder, and A. Sannino, “An adaptive control system for a dc microgrid for data centers,” IEEE Trans. Ind. Appl., vol. 44, no. 6, pp. 1910–1917, Nov./Dec. 2008.
  11. D. Salomonsson and A. Sannino, “Low-voltage dc distribution system for commercial power systems with sensitive electronic loads,” IEEE Trans. Power Del., vol. 22, no. 3, pp. 1620–1627, Jul. 2007.